10 Apr 2013

SMARTSENS: first family of analytical sensors that no longer require transmitters

  • 2-wire loop powered analytical sensors with integrated transmitter technology
  • Direct connection of sensors to process control system via 4...20 mA/HART
  • Installation in explosive (zone 0) and hygienic areas
  • Configuration and offline calibration via PACTware (FDT/DTM) or HART DD

SMARTSENS

SMARTSENS 2-wire loop powered analytical sensors with integrated transmitter technology (left to right: SMARTSENS ORP 8510, SMARTSENS PH 8150, SMARTSENS PH 8570, SMARTSENS COND 7200)

The year 2013 marks a turning point in analysis: KROHNE introduces SMARTSENS, the first family of 2-wire loop powered analytical sensors with integrated transmitter technology. SMARTSENS sensors significantly reduce the risk of failures along the chain from sensor to process control system and ease the handling of analytical sensors in a revolutionary way. The first step includes the sensors for pH, ORP and conductivity, followed by other parameters.

Until today, analytical sensors require an external (proprietary) transmitter on site that translates the sensor signals to the process control system. Considering the possible error by the requirements of IEC 61508/IEC 61511 in the chain from sensor to process control system, the transmitter represents the main source of error in percentage. False installation, cabling or configuration of the transmitter are frequently occurring problems. To eliminate these risks, KROHNE miniaturised the transmitter and fitted it into the sensor head: Any SMARTSENS sensor can be connected directly to the process control system, featuring direct communication via 4…20 mA/HART. Hereby, KROHNE is the first provider to offer a direct connection from sensor to the process control system via a standardised fieldbus.

Due to influences such as medium, temperature, humidity, environmental conditions or pollution, analytical sensors lose their accuracy over time and need to be calibrated, cleaned, regenerated and ultimately replaced. Today, most of the analytical sensors in the field use analog technology and have to be calibrated on site together with the transmitter, even if they are installed at remote or difficult-to-reach measuring points under open sky. This presents far from ideal conditions for a calibration which may result in false values in the process control system. Here, SMARTSENS offers a secure alternative: all SMARTSENS sensors are digital sensors and can be (re-)calibrated offline in a laboratory under controlled conditions. The sensors will store the calibration data and can just be plugged in again on site. For offline calibration, the sensor can be connected directly to a PC running the same PACTware (FDT/DTM) as applied in the assetmanagement system, using an USB interface cable for bi-directional HART 7 communication and power supply.

Target industries for SMARTSENS include chemical, pharmaceuticals, food and beverage as well as power, water and wastewater applications. Each SMARTSENS sensor is specifically designed for its area of application: approvals and certificates range from installation in explosive areas (zone 0) to hygienic areas. Along with the sensor family, KROHNE introduces a large portfolio of accessories, including loop powered displays, USB interface cable and mounting assemblies.

About KROHNE

KROHNE is a full-service provider for process measuring technology for the measurement of flow, mass flow, level, pressure and temperature as well as analytical tasks. Founded in 1921 and headquartered in Duisburg, Germany, the company employs over 3,700 people all over the world and is present on all continents. KROHNE stands for innovation and maximum product quality and is one of the market leaders in industrial process measuring technology.

Contact

Issued by:
KROHNE Messtechnik GmbH
Ludwig-Krohne-Str. 5
47058 Duisburg
www.krohne.com

Contact for editors:
Jörg Holtmann, PR Manager
Tel:  +49 203 301 4511
Fax: +49 203 301 105 11
eMail: j.holtmann@krohne.com