OPTISENS TUR 2000

Optical turbidity sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…4/40/400 NTU/FNU; Max. +50°C / +122°F; 6 bar / 87 psi
  • 90° scattered light (NIR-LED) measurement acc. to ISO 7027

OPTISENS TUR 2000

Optical turbidity sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…4/40/400 NTU/FNU; Max. +50°C / +122°F; 6 bar / 87 psi
  • 90° scattered light (NIR-LED) measurement acc. to ISO 7027

Overview

The OPTISENS TUR 2000 is a turbidity sensor for use in open channels. Its robust design is especially suitable for potable water and wastewater applications. The NIR-LED (90° scattered light acc. to ISO 7027) guarantees a short response time and a precise turbidity measurement (<40 FNU/NTU). The turbidity sensor is available as insertion version for flow cell installation in water treatment plants and as immersion version for installation in open basins and channels of wastewater treatment plants and other facilities. The OPTISENS TUR 2000 operates with the OPTISENS MAC 100 analytical transmitter.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Precise turbidity measurement <40 FNU/NTU through the 90° scattered light method (acc. to ISO 7027)
  • Long-term stability due to reduced clogging by integrated spray cleaning nozzle (immersion version only)
  • Robust design for open channel measurement and a long lifespan
  • Short response time for all applications
  • Mounting option on a flexible telescopic rod ( SENSOFIT IMM 2000 ) or in a flow-through assembly ( SENSOFIT FLOW 2000 Flow Cell)
  • For connection to the MAC 100 or any suitable analytical transmitter

Related products

SENSOFIT IMM 2000

Immersion assembly for general water and wastewater treatment applications

  • For use with OPTISENS ODO/ADO/TUR 2000, OPTISENS TSS 2000/3000 or sensors with NPT thread
  • Sensor connection: ¾ NPT, 1¼ NPT (female); Process connection: Telescopic rod holder mounted to handrail
  • Immersion length: flexible, max. 4 m / 13.1 ft
  • Max. +60°C / +140°F, pressureless

SENSOFIT FLOW 2000 C

Flow-through assembly for water and wastewater applications

  • For use with optical oxygen and turbidity sensors OPTISENS ODO and TUR 2000 (inline versions)
  • Sensor connection: union nut; Process connection: hose connection
  • For measurement in small sample streams
  • Max. +50°C / +122°F and 6 bar / 87 psi

MAC 100

Liquid analytical transmitter for measurements with sensors of the OPTISENS portfolio

  • Output: 3 x 4…20 mA, 3 relays (mechanical)
  • Input: max. 2 x sensor, 2 x temperature
  • -15…+55°C / +5…+131°F (ambient)
  • Robust housing for wall-mount installation